Vaisala HMP60 Humidity & Temperature Probe

Features

  • Miniature-size humidity probe
  • Low power consumption
  • Measurement range: 0 … 100 %RH; −40 … +60 °C (−40 … +140 °F)
  • Cable detachable with standard M8 connector
  • Rugged metal housing
  • Interchangeable INTERCAP sensor
  • Optional RS-485 digital output supports Modbus RTU
  • Optional dew point, wet bulb temperature, absolute humidity, mixing ratio, and enthalpy output
Enquiry
Category:

Dpstar is a leader in environmental and industrial measurements. Curiosity and innovation are core values in our company. Our extensive knowledge and expertise are materialized in our selection of innovative products. Accurate measurements are essential for healthy indoor air and improving the energy efficiency of buildings. The unique, cutting-edge Dpstar sensor technologies are manifested throughout our versatile range of products. The transmitters have an exceptionally long lifetime and excellent measurement stability, thus being practically maintenance-free. These are among the many reasons why Dpstar’s products are a sustainable choice.

HMP60 is a simple, durable, and cost-effective humidity probe suitable for volume applications, integration into other manufacturers’ equipment, incubators, glove boxes, greenhouses, fermentation chambers, and data loggers.

Dimensions

 

Benefits

  • Easy Installation
    The probe cable has a screw-on quick connector for easy installation. Different cable lengths are available. Also other compatible M8 series cables can be used. Accessories are available for different installation needs.
  • Low Current Consumption
    HMP60 is suitable for battery-powered applications because of its very low current consumption.
  • Several Outputs
    Temperature measurement is a standard feature in HMP60, with dew point temperature, wet bulb temperature, absolute humidity, mixing ratio, and enthalpy as optional calculated parameters. Four voltage output ranges are available. An optional RS-485 output with Modbus support is also available.
  • Rugged Design
    HMP60 is designed for extreme conditions. The stainless steel body of HMP60 is classified as IP65. The probe has a sealed structure and the sensor is protected by a membrane filter and a plastic grid, or optionally by a stainless steel filter.
  • Recalibration Not Needed
    The INTERCAP sensor is interchangeable. No recalibration is required; the sensor can simply be replaced, also in the field.

Specification

Relative humidity
Measurement range 0 … 100 %RH
Typical accuracy
at 0 … +40 °C (+32 … +140 °F) ±3 %RH (0 … 90 %RH)
±5 %RH (90 … 100 %RH)
at −40 … 0 °C and +40 … +60 °C (−40 … +32 °F and +104 … +140 °F) ±5 %RH (0 … 90 %RH)
±7 %RH (90 … 100 %RH)
Temperature
Measurement range −40 … +60 °C (−40 … +140 °F)
Accuracy
at +10 … +30 °C (+50 … +86 °F)
at −40 … +10 and +30 … +60 °C
(−40 … +50 and +86 … +140 °F)
±0.5 °C (±32.9 °F)
±0.6 °C (±33.08 °F)
Analog outputs
Accuracy at +20 °C (+68 °F) ±0.2 % of FS
Temperature dependence ±0.01 % of FS/°C (±0.006 % of FS/°F)
Operating environment
Operating temperature −40 … +60 °C (−40 … +140 °F)
EMC compliance EN 61326-1, industrial environment
Inputs and outputs
Power consumption 1 mA average, max. peak 5 mA
Operating voltage (1)
With 1 V / 2.5 V output 5 … 28 VDC
With 5 V output 8 … 28 VDC
With loop power converter 8 … 28 VDC
With digital output 5 … 28 VDC
Start-up time
Probes with analog output 4 s at operating voltage
13.5 … 16.5 VDC
2 s at other valid operating voltages
Probes with digital output 1 s
Outputs
2 channels 0 … 1 VDC / 0 … 2.5 VDC / 0 … 5 VDC /
1 … 5 VDC
1-channel loop-power converter (separate module, compatible with
humidity accuracy only)
4 … 20 mA
Digital output (optional) RS-485 2-wire half duplex, supports
Modbus RTU
External loads
0 … 1 V RL min. 10 kΩ
0 … 2.5 V /0 … 5 V RL min. 50 kΩ
Output parameters
Relative humidity, temperature, dew point temperature, wet bulb temperature, absolute humidity, mixing ratio, enthalpy
(1) Use lowest available operating voltage to minimize heating.
Mechanical
IP rating IP65 (1)
Body thread MI2x1 / 10 mm (0.4 in)
Cable connector 4-pin M8 (IEC 60947-5-2)
Materials
Body Stainless steel (AISI 316)
Grid filter Chrome coated ABS plastic
Cable Polyurethane or FEP
Weight
Probe 17 g (0.6 oz)
Probe with 0.3 m (1 ft) cable 28 g (1 oz)
(1) Applicable with stainless steel sintered filter and PTFE sintered filter only
Spare Parts & Accessories
Sensors
INTERCAP sensor, 1 pc 15778HM
INTERCAP sensor, 10 pcs INTERCAPSET-10PCS
Sensor protection
Plastic grid filter DRW010522SP
Membrane filter DRW010525SP
Stainless steel sintered filter HM46670SP
PTFE membrane filter with stainless steel grid ASM212652SP
PTFE sintered filter DRW244938SP
Probe installation
Probe mounting clamp set, 10 pcs 226067
Probe mounting flange 226061
Probe holder, 5 pcs ASM213382SP
Plastic M12 installation nuts, pair 18350SP
Flat extension cable 1 m (3 ft) (1) CBL210649SP
Connection adapters
4 … 20 mA loop power converter  UI-CONVERTER-1CB
Mounting bracket for converter 225979
USB cable for PC connection 219690
Connection cable for MI70 indicator  219980SP
Connection Cables With Open Wires
+60 °C 0.3 m (+140 °F 1 ft) HMP50Z032SP
+60 °C 1.2 m (+140 °F 4 ft) HMP50Z120
+60 °C 3 m (+140 °F 9.8 ft) HMP50Z300SP
+80 °C 1.5 m (+176 °F 5 ft) 225777SP
+80 °C 3 m (+176 °F 10 ft) 225229SP
+180 °C 1.5 m (+356 °F 5 ft) FEP 238025
+180 °C 3 m (+356 °F 10 ft) FEP  226902SP
(1) Connection cable 219980SP is also needed if this cable is used with MI70 indicator

Download

Vaisala HMP60 Humidity & Temperature Probe_DpstarGroup

Reviews

There are no reviews yet.

Be the first to review “Vaisala HMP60 Humidity & Temperature Probe”

Your email address will not be published. Required fields are marked *