Features

– 160 × 120 resolution in thermal channel, high sensitivity sensor.
– Point, line and area for temperature measurement
– Temperature Range: 30°C to 45°C
– Temperature Accuracy: ±0.5 °C
– Reliable temperature exception alarm function
– 3D DNR, image detail enhancement
– Strobe light and audio alarm

Enquiry

Thermal Human Body Fever Scanners are ideal equipment for you to conduct screening safetly and efficiently of those who may potentially be infected with flu. Body temperature of those infected is expected to be around 38~39DegC while adult normal temperature should be around 36DegC. This Scanner can visualize such as temperature difference instantly from safe distance for you to segregate those who may have been infected. Dpstar Group is a top supplier of thermal human body fever scanners & thermometer in Malaysia. We offer a wide range of thermometer, thermal imager and body scanner for fever screening.

Thermographic Turret Body Temperature Measurement Camera is able to measure the object’s temperature at high accuracy in real-time. It is capable to discover and track people with higher body temperature among the crowded public area, it can be widely used in places such as customs, airport, school and hospital for inspection and quarantine.

Specification

Thermal Module
Image Sensor Vanadium Oxide Uncooled Focal Plane Arrays
Max. Resolution 160 × 120 (the resolution of output image is 320 × 240)
Pixel Interval 17 μm
Response Waveband 8 μm to 14 μm
NETD Less than 40 mK (25°C), F# = 1.1
Lens (Focal Length) 6.2 mm
IFOV 2.74 mrad
Field of View 25.0° × 18.7° (H × V)
Min. Focusing Distance 0.6 m
Aperture F1.1
Optical Module
Max. Image Resolution 2688 × 1520
Image Sensor 1/2.7″ Progressive Scan CMOS
Min. Illumination Color: 0.0089 Lux @ (F1.6, AGC ON), B/W: 0.0018 Lux @ (F1.6, AGC ON)
Shutter Speed 1s to 1/100,000s
Lens (Focal Length) 8 mm
Field of View 39.42° × 22.14°(H × V)
WDR 120 dB
Day & Night IR cut filter with auto switch
Image Function
Bi-spectrum Image Fusion Fusion view of thermal view and overlaid details of the optical channel
Picture in Picture Combines details of thermal and optical image PIP, overlay thermal image on optical image
Smart Function
VCA (Video Content Analysis) 4 VCA rule types (Line Crossing, Intrusion, Region Entrance, and Region Exiting), up to 8 VCA rules totally.
Temperature Measurement 3 temperature measurement rule types, 21 rules (10 points, 10 areas, and 1 line).
Temperature Range 30 °C to +45 °C
Temperature Accuracy ± 0.5°C
Fire detection Dynamic fire point detection, up to 10 fire points detectable.
Infrared
IR Distance Up to 15 m
IR Intensity and Angle Automatically adjusted
Network
Main Stream Visible Light: 50Hz: 25fps (2688 × 1520), 25fps (1920 × 1080), 25fps (1280 × 720)
Visible Light: 60Hz: 30fps (2688 × 1520), 30fps (1920 × 1080), 30fps (1280 × 720)
Thermal: 1280 × 720, 704 × 576, 640 × 480, 352 × 288, 320 × 240
Sub-Stream Visible Light: 50Hz: 25fps (704 × 576), 25fps (352 × 288), 25fps (176 × 144)
Visible Light: 60Hz: 30fps (704 × 480), 30fps (352 × 240), 30fps (176 × 120)
Thermal: 704 × 576, 352 × 288, 320 × 240
Video Compression H.265/H.264/MJPEG
Audio Compression G .711u/G.711a/G.722.1/MP2L2/G.726/PCM
Protocols TCP/IP, ICMP, HTTP, HTTPS, FTP, DHCP, DNS, DDNS, RTP, RTSP, RTCP, PPPoE, NTP
UPnP, SMTP, SNMP, IGMP, 802.1X, QoS, IPv6, UDP, Bonjour
Simultaneous Live View Up to 20
User/Host Leve Up to 32 users, 3 levels: Administrator, Operator, User
Security Measures User authentication (ID and PW), MAC address binding, HTTPS encryption, IEEE 802.1x
access control, IP address filtering
Integration
Alarm Input 1-ch inputs (0-5 VDC)
Alarm Output 1-ch relay outputs, alarm response actions configurable
Alarm Action SD recording/relay output/smart capture/FTP upload/email linkage/ audio
alarm/white light alarm
Audio Input 1, 3.5 mm Mic in/Line in interface. Line input: 2 – 2.4 V [p-p], output impedance: 1 KΩ ± 10%
Audio Output Linear level; impedance: 600 Ω
Reset 1 Reset Button
Communication Interface 1, RJ45 10M/100M Self-adaptive Ethernet interface. 1, RS-485 interface
SD Memory Card Built-in MicroSD card slot, supporting MicroSD/SDHC/SDXC card (up to 256 G),
supports manual/alarm recording
Analog Video Output 1.0 V [p-p]/75 Ω, PAL/NTSC
Application Programming Open-ended API, supporting ISAPI, HIKVISION SDK, and third-party management
platform
Client iVMS-4200, Hik-Connect
Web Browser IE9+, chrome31-44, Firefox 30-51, Safari 5.02+ (mac)
General
Menu Language 32 languages
English, Russian, Estonian, Bulgarian, Hungarian, Greek, German, Italian, Czech, Slovak
French, Polish, Dutch, Portuguese, Spanish, Romanian, Danish, Swedish, Norwegian,
Finnish, Croatian, Slovenian, Serbian, Turkish, Korean, Traditional Chinese, Thai,
Vietnamese, Japanese, Latvian, Lithuanian, Portuguese (Brazil)
Power 12 VDC ± 20%, two-core terminal block
PoE (802.3af, class 3)
Power Consumption 12 VDC ± 20%: 0.5 A, max. 6 W
PoE (802.3af, class 3): 42.5 V to 57 V, 0.14 A to 0.22 A, max. 6.5 W
Working Temperature/Humidity 20 °C to 50 °C
95% or less
Protection Level IP66 Standard, TVS 6000V Lightning protection, surge protection, voltage transient protection
Dimension 138.3 mm × 138.3 mm × 123.1 mm (5.45 ” × 5.45″ × 4.85 “)
Weight 940 g (2.07 lb)